Our Products:     Note: For information of our LED products,please visit www.hyrite.com.Thank you
 
  Electronic Transformer
  UL 2161 DM/FL
  CE 20mA
  CE 40mA or higher
  General 20-30mA
  General 40mA or higher
  Built-in Dimmer,Flasher...
  Magnetic Neon Transformer
  General Type
  UL 2161
  European Type
  Electronic Ballast
  EBO HO Sign Ballast
  EBC Commercial Ballast
  Electrode
  Neon Tubing
  Neon Accessories
  Vacuum System
  Rare Gases
  HT Cable
  Electrode Cover
  Neon Tube Support
  Neon Testing Tools
  Miscellaneous
  Glass Stopcock
  Burner & Hand Torch
  Microcomputer Timer Switch
Me-120-12000-30, Me-120-9000-30, Me-120-6000-30, Me-120-3000-30 UL2161 Series --- with Optional Dimming Switch
Features:
- UL 2161 standard.
- Ground-fault protection.
- Open circuit protection.
- No mercury migration or "jelly-bean" effect.
- Optional built-in dimming switch.
Environmental Specifications :
- Operating temperature: -25℃~+40℃
- Cooling: Convection
- Indoor type 7 for dry or damp location
Certificates & Standards :
- UL 2161
  Model   Me-120-3000-30
  Size LXWXH(mm)   120*44*30
  Weight(kg)   0.3
  Input   120VAC 50/60Hz 0.5A
  Power   36W
  Output   3kV 30mA
  Power factor   PF>0.9,THD<45%
  Working frequency   40-41KHz
  Over-load protection   Yes
  Open-circuit protection   Yes
  Earth-leakage protection   Yes
  IP Rating   Indoor type 7
  Input cable   2m
  Input plug   Yes
  Input switch   Switch on the cord
  Output cable   0.6m
  Ext. dimming control app.   No
  Ext. flashing control app.   Yes
  Loading Length Data Sheet
  Diameter Tubing(mm)
7
8
9
10
11
12
13
15
18
17
15
13
12
11
10
9
3
3
4
4
5
6
6
8
3
3
4
5
5
7
8
9
  Gas Pressure(mmHg)
  Load length(ft.)Clear/Neon
  Load length(ft.)Mercury/Argon
  Model   Me-120-6000-30
  Size LXWXH(mm)   147*67*43
  Weight(kg)   0.60
  Input   120VAC 50/60Hz 0.5A
  Power   60W
  Output   5kV 30mA
  Power factor   PF>0.9,THD<45%
  Working frequency   38-40KHz
  Over-load protection   Yes
  Open-circuit protection   Yes
  Earth-leakage protection   Yes
  IP Rating   Indoor type 7
  Input cable   2m
  Input plug   Yes
  Input switch   Pull chain switch
  Output cable   0.8m
  Ext. dimming control app.   No
  Ext. flashing control app.   Yes
  Loading Length Data Sheet
  Diameter Tubing(mm)
7
8
9
10
11
12
13
15
18
17
15
13
12
11
10
9
5
6
7
8
10
12
13
14
6
7
8
9
11
14
15
18
  Gas Pressure(mmHg)
  Load length(ft.)Clear/Neon
  Load length(ft.)Mercury/Argon
  Model   Me-120-9000-30
  Size LXWXH(mm)   147*67*43
  Weight(kg)   0.60
  Input   120VAC 50/60Hz 0.75A
  Power   90W
  Output   6.5kV 30mA
  Power factor   PF>0.9,THD<45%
  Working frequency   36-38KHz
  Over-load protection   Yes
  Open-circuit protection   Yes
  Earth-leakage protection   Yes
  IP Rating   Indoor type 7
  Input cable   2m
  Input plug   Yes
  Input switch   Pull chain switch
  Output cable   0.8m
  Ext. dimming control app.   No
  Ext. flashing control app.   Yes
  Loading Length Data Sheet
  Diameter Tubing(mm)
7
8
9
10
11
12
13
15
18
17
15
13
12
11
10
9
9
10
11
14
17
20
22
25
11
11
14
18
20
24
25
31
  Gas Pressure(mmHg)
  Load length(ft.)Clear/Neon
  Load length(ft.)Mercury/Argon
  Model   Me-120-12000-30
  Size LXWXH(mm)   176*94*47
  Weight(kg)   1.00
  Input   120VAC 50/60Hz 0.9A
  Power   108W
  Output   8kV 30mA
  Power factor   PF>0.9,THD<45%
  Working frequency   23-25KHz
  Over-load protection   Yes
  Open-circuit protection   Yes
  Earth-leakage protection   Yes
  IP Rating   Indoor type 7
  Input cable   2m
  Input plug   Yes
  Input switch   Pull chain switch
  Output cable   0.8m
  Ext. dimming control app.   No
  Ext. flashing control app.   Yes
  Loading Length Data Sheet
  Diameter Tubing(mm)
7
8
9
10
11
12
13
15
18
17
15
13
12
11
10
9
12
14
16
19
23
27
30
34
14
16
19
23
27
32
35
42
  Gas Pressure(mmHg)
  Load length(ft.)Clear/Neon
  Load length(ft.)Mercury/Argon
Notes:
- The above maximum loading length figures are for reference only. The actual loading capability may vary due to different installation methods or environmental factors. Electrodes calculations are included, no need to deduct the length for electrodes.
- The tubing diameters not indicated above are not recommended to be used with the power supply.
- length figures for mercury filled tubes are based on operation in temperatures above 4℃(40).Deduct 25% from the figures for operation below 4℃(40)
Next Series

Me-120-Series