Features: -Maximum output current is 40mA, suitable for neon application with higher current and brightness requirement. - Input circuit contains no electrolysis capacitance, thus causing no starting surge. Suitable for large flashing units, scanning control units, dimming control units, continuous-operating units. - Built- in open circuit protection,thermal protection and external surge protector. |
Environmental Specifications : - Operating temperature: -25℃ ~ +40℃ - Cooling: Convection - Relative humidity: 5% to 100% - Installation: Indoor or Outdoor |
Certificates & Standards : - GB19510 |
 |
Model |
XP-7500-40 |
Size LXWXH(mm) |
252*57*39 |
Weight(kg) |
0.9 |
Input |
220-240VAC 50/60Hz 600mA |
Power |
144W |
Output |
7.5kV AC 40mA |
Power factor |
PF>0.9, THD<38% |
Working frequency |
37-40KHz |
Over-load protection |
Yes |
Open-circuit protection |
Yes |
Earth-leakage protection |
N/A |
IP Rating |
IP 66 |
Input cable |
0.35m |
Input plug |
No |
Input switch |
No |
Output cable |
0.5m |
Ext.dimming control app. |
No |
Ext.flashing control app. |
Yes |
Diameter Tubing(mm) |
12 |
13 |
15 |
18 |
20 |
11 |
10 |
9 |
8 |
7 |
23 |
26 |
30 |
36 |
39 |
26 |
30 |
36 |
39 |
46 |
7 |
8 |
9 |
11 |
12 |
8 |
9 |
11 |
12 |
14 |
|
Gas Pressure(mmHg) |
Load length(ft.)Clear/Neon |
Load length(ft.)Mercury/Argon |
Load length(m)Clear/Neon |
Load length(m)Mercury/Argon |
|
 |
Model |
XP-10000-40 |
Size LXWXH(mm) |
288*67*45 |
Weight(kg) |
1.4 |
Input |
220-240VAC 50/60Hz 800mA |
Power |
192W |
Output |
10kV AC 40mA |
Power factor |
PF>0.9, THD<38% |
Working frequency |
26-28KHz |
Over-load protection |
Yes |
Open-circuit protection |
Yes |
Earth-leakage protection |
N/A |
IP Rating |
IP 66 |
Input cable |
0.35m |
Input plug |
No |
Input switch |
No |
Output cable |
0.5m |
Ext.dimming control app. |
No |
Ext.flashing control app. |
Yes |
Diameter Tubing(mm) |
12 |
13 |
15 |
18 |
20 |
11 |
10 |
9 |
8 |
7 |
30 |
33 |
39 |
46 |
56 |
33 |
39 |
46 |
56 |
62 |
9 |
10 |
12 |
14 |
17 |
10 |
12 |
14 |
17 |
19 |
|
Gas Pressure(mmHg) |
Load length(ft.)Clear/Neon |
Load length(ft.)Mercury/Argon |
Load length(m)Clear/Neon |
Load length(m)Mercury/Argon |
|
Notes:
- The above maximum loading length figures are for reference only. The actual loading capability may vary due to different installation methods or environmental factors. Electrodes calculations are included, no need to deduct the length for electrodes.
- The tubing diameters not indicated above are not recommended to be used with the power supply.
- length figures for mercury filled tubes are based on operation in temperatures above 4℃(40 ).Deduct 25% from the figures for operation below 4℃(40 ) |
|
XP Series ---- Extra High Voltage High Frequency Output Models |