Features: - 50% energy saving over conventional transformers.
- No gas tubes discoloration or mercury migration, Ideal for mercury tubes.
- Completely sealed and waterproof, suitable for indoor/outdoor installation. - Safe and reliable with built-in open circuit protection and thermal protection. - Support for connection not exceeding 2 meters of high voltage output wire. |
Environmental Specifications : - Operating temperature: -25℃~+40℃ - Cooling: Convection - Relative humidity: 5% to 100% - Installation: Indoor or Outdoor |
Certificates & Standards : - GB19510 |
*Available for 240V and 120V. |
 |
MODEL |
NP-3000-30 |
Size LXWXH(mm) |
83*42*34 |
Weight(kg) |
0.18 |
Input |
220-240VAC 50Hz 100mA |
Power |
24W |
Output |
3kV AC 30mA |
Power factor |
PF>0.95, THD<30% |
Working frequency |
40-45KHz |
Over-load protection |
Yes |
Open-circuit protection |
Yes |
Earth-leakage protection |
N/A |
IP Rating |
IP 66 |
Input cable |
0.3m |
Input plug |
optional |
Input switch |
No |
Output cable |
0.3m |
Ext.dimming control app. |
Yes |
Ext.flashing control app. |
Yes |
Diameter Tubing(mm) |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
15 |
18 |
17 |
15 |
13 |
12 |
11 |
10 |
9 |
3 |
3 |
4 |
5 |
5 |
6 |
6 |
8 |
3 |
3 |
4 |
5 |
5 |
6 |
8 |
9 |
0.6 |
0.6 |
1.2 |
1.2 |
1.5 |
1.8 |
1.8 |
2.4 |
0.6 |
0.6 |
1.2 |
1.5 |
1.5 |
1.8 |
2.4 |
2.7 |
|
Gas Pressure(mmHg) |
Load length(ft.)Clear/Neon |
Load length(ft.)Mercury/Argon |
Load length(m)Clear/Neon |
Load length(m)Mercury/Argon |
|
 |
Model |
NP-7500-30 |
Size LXWXH(mm) |
147*57*35 |
Weight(kg) |
0.38 |
Input |
220-240VAC 50Hz 300mA |
Power |
72W |
Output |
7.5kV AC 30mA |
Power factor |
PF>0.9, THD<30% |
Working frequency |
34-37KHz |
Over-load protection |
Yes |
Open-circuit protection |
Yes |
Earth-leakage protection |
N/A |
IP Rating |
IP 66 |
Input cable |
0.35m |
Input plug |
optional |
Input switch |
No |
Output cable |
0.5m |
Ext.dimming control app. |
Yes |
Ext.flashing control app. |
Yes |
Diameter Tubing(mm) |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
15 |
18 |
17 |
15 |
13 |
12 |
11 |
10 |
9 |
8 |
9 |
9 |
12 |
15 |
18 |
20 |
23 |
9 |
9 |
12 |
15 |
18 |
20 |
23 |
28 |
2.4 |
2.7 |
3.0 |
3.6 |
4.5 |
5.4 |
6.0 |
6.9 |
2.7 |
3.0 |
3.6 |
4.5 |
5.4 |
6.0 |
6.9 |
8.4 |
|
Gas Pressure(mmHg) |
Load length(ft.)Clear/Neon |
Load length(ft.)Mercury/Argon |
Load length(m)Clear/Neon |
Load length(m)Mercury/Argon |
|
 |
Model |
NP-10000-30 |
SIZE LXWXH(mm) |
166*65*55 |
Weight(kg) |
0.62 |
Input |
220-240VAC 50Hz 400mA |
Power |
96W |
Output |
10kV AC 30mA |
Power factor |
PF>0.9, THD<30% |
Working frequency |
21-24KHz |
Over-load protection |
Yes |
Open-circuit protection |
Yes |
Earth-leakage protection |
N/A |
IP Rating |
IP 66 |
Input cable |
0.35m |
Input plug |
optional |
Input switch |
No |
Output cable |
0.5m |
Ext.dimming control app. |
Yes |
Ext.flashing control app. |
Yes |
Diameter Tubing(mm) |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
15 |
18 |
17 |
15 |
13 |
12 |
11 |
10 |
9 |
11 |
12 |
14 |
16 |
20 |
23 |
25 |
30 |
12 |
14 |
15 |
20 |
23 |
25 |
30 |
35 |
3.3 |
3.6 |
4.2 |
4.8 |
6.0 |
6.9 |
7.5 |
9.0 |
3.6 |
4.2 |
4.5 |
6 |
6.9 |
7.5 |
9.0 |
10.5 |
|
Gas Pressure(mmHg) |
Load length(ft.)Clear/Neon |
Load length(ft.)Mercury/Argon |
Load length(m)Clear/Neon |
Load length(m)Mercury/Argon |
|
 |
MODEL |
NP-12000-30 |
Size LXWXH(mm) |
157*97*48 |
Weight(kg) |
1.1 |
Input |
220-240VAC 50Hz 500mA |
Power |
120W |
Output |
12kV AC 30mA |
Power factor |
PF>0.9, THD<30% |
Working frequency |
21-24KHz |
Over-load protection |
Yes |
Open-circuit protection |
Yes |
Earth-leakage protection |
N/A |
IP Rating |
IP 66 |
Input cable |
0.5m |
Input plug |
optional |
Input switch |
No |
Output cable |
0.5m |
Ext.dimming control app. |
Yes |
Ext.flashing control app. |
Yes |
Diameter Tubing(mm) |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
15 |
18 |
17 |
15 |
13 |
12 |
11 |
10 |
9 |
12 |
14 |
16 |
19 |
23 |
27 |
30 |
35 |
14 |
16 |
19 |
23 |
28 |
33 |
35 |
40 |
3.6 |
4.2 |
4.8 |
5.7 |
6.9 |
8.1 |
9.0 |
10.5 |
4.2 |
4.8 |
5.7 |
6.9 |
8.4 |
9.9 |
10.5 |
12 |
|
Gas Pressure(mmHg) |
Load length(ft.)Clear/Neon |
Load length(ft.)Mercury/Argon |
Load length(m)Clear/Neon |
Load length(m)Mercury/Argon |
|
Notes:
- The above maximum loading length figures are for reference only. The actual loading capability may vary due to different installation methods or environmental factors. Electrodes calculations are included, no need to deduct the length for electrodes.
- The tubing diameters not indicated above are not recommended to be used with the power supply.
- length figures for mercury filled tubes are based on operation in temperatures above 4℃(40 ).Deduct 25% from the figures for operation below 4℃(40 ) |
|