Our Products:     Note: For information of our LED products,please visit www.hyrite.com.Thank you
 
  Electronic Transformer
  UL 2161 DM/FL
  CE 20mA
  CE 40mA or higher
  General 20-30mA
  General 40mA or higher
  Built-in Dimmer,Flasher...
  Magnetic Neon Transformer
  General Type
  UL 2161
  European Type
  Electronic Ballast
  EBO HO Sign Ballast
  EBC Commercial Ballast
  Electrode
  Neon Tubing
  Neon Accessories
  Vacuum System
  Rare Gases
  HT Cable
  Electrode Cover
  Neon Tube Support
  Neon Testing Tools
  Miscellaneous
  Glass Stopcock
  Burner & Hand Torch
  Microcomputer Timer Switch
NPS-n220Series EMC & LVD Tested Models  
Features:
- Suitable for indoor applications, such as window sign or hanging sign.
- Complies with CE EMC & LVD standard.
- No mercury migration or "jelly-bean" effect.
Environmental Specifications :
- Operating temperature: -25℃~+40℃
- Cooling: Convection
- Relative humidity: 5% to 100%
- Installation: indoor only
Certificates & Standards :
- CE-EMC:EN 55015; EN 61547; EN 61000-3-2; EN 31000-3-3
- CE-LVD: EN 61347-2-10; EN 61347-1
  Model   NPS-4220
  Size LXWXH(mm)   132*78*46
  Weight(kg)   0.70
  Input   220-240VAC 50Hz 0.2A
  Power   48W
  Output   4kV AC 30mA
  Power factor   PF>0.9,THD<25%
  Working frequency   39KHz
  Over-load protection   Yes
  Open-circuit protection   Yes
  Earth-leakage protection   N/A
  IP Rating   IP 44
  Input cable   2m
  Input plug   Yes
  Input switch   Pull chain switch
  Output cable   0.6m
  Ext. dimming control app.   No
  Ext. flashing control app.   Yes
  Loading Length Data Sheet
  Diameter Tubing(mm)
7
8
9
10
11
12
13
15
18
17
15
13
12
11
10
9
7
8
9
11
13
16
16
20
8
9
11
12
15
18
20
23
  Gas Pressure(mmHg)
  Load length(ft.)Clear/Neon
  Load length(ft.)Mercury/Argon
  Model   NPS-6220
  Size LXWXH(mm)   132*78*46
  Weight(kg)   0.70
  Input   220-240VAC 50Hz 0.3A
  Power   72W
  Output   6kV AC 30mA
  Power factor   PF>0.9,THD<25%
  Working frequency   38KHz
  Over-load protection   Yes
  Open-circuit protection   Yes
  Earth-leakage protection   N/A
  IP Rating   IP 44
  Input cable   2m
  Input plug   Yes
  Input switch   Pull chain switch
  Output cable   0.6m
  Ext. dimming control app.   No
  Ext. flashing control app.   Yes
  Loading Length Data Sheet
  Diameter Tubing(mm)
7
8
9
10
11
12
13
15
18
17
15
13
12
11
10
9
11
13
15
19
22
26
30
33
13
15
18
23
26
31
33
39
  Gas Pressure(mmHg)
  Load length(ft.)Clear/Neon
  Load length(ft.)Mercury/Argon
  Model   NPS-9220
  Size LXWXH(mm)   176*94*47
  Weight(kg)   1.09
  Input   220-240VAC 50Hz 0.45A
  Power   108W
  Output   9kV AC 30mA
  Power factor   PF>0.9,THD<25%
  Working frequency   24KHz
  Over-load protection   Yes
  Open-circuit protection   Yes
  Earth-leakage protection   N/A
  IP Rating   IP 44
  Input cable   2m
  Input plug   Yes
  Input switch   Pull chain switch
  Output cable   0.6m
  Ext. dimming control app.   No
  Ext. flashing control app.   Yes
  Loading Length Data Sheet
  Diameter Tubing(mm)
7
8
9
10
11
12
13
15
18
17
15
13
12
11
10
9
16
18
21
25
30
34
39
44
18
21
25
30
36
41
46
54
  Gas Pressure(mmHg)
  Load length(ft.)Clear/Neon
  Load length(ft.)Mercury/Argon
Notes:
- The above maximum loading length figures are for reference only. The actual loading capability may vary due to different installation methods or environmental factors. Electrodes calculations are included, no need to deduct the length for electrodes.
- The tubing diameters not indicated above are not recommended to be used with the power supply.
- length figures for mercury filled tubes are based on operation in temperatures above 4℃(40).Deduct 25% from the figures for operation below 4℃(40)
Next Series